Testing service range
PONY TEST has the certificate accredited by CNAL and CMA. With professional skills and the spirit of justice, PONY TEST provide professional environmental testing service in water quality, soil, air, noise, etc. For example, environmental impact evaluation, environmental training, indoor environmental quality, occupational health testing and evaluation, project acceptance, the oil and gas recovery testing for gas stations and oil depots, the testing for introducing ISO 14000 and 18,000system into manufacturer, etc.
The testing for environmental pollution in process of manufacture
Environmental management is a comprehensive management, involving all aspects of the enterprise. Raising the level of environmental management must promote and enhance the whole level of management, which is conducive to promote Chinese economy from extensive operation which is high consumption, waste Large, low efficiency, poor efficiency, to intensive management.
Enterprises introduce ISO 14000 standards can promote enterprises establish self-regulatory mechanism by themselves, institute and implement a prevention-oriented management, which gasping from the source, controlling the entire process. ISO14000 series standards emphasize both environmental pollution and the reduction in resources, energy consumption at the same time, so that they could effectively promote the enterprises use the resources and energy in reason. At the same time, enterprises carry out ISO14001, the uniform international environmental management standards, are conducive to achieving bilateral and multilateral mutual recognition of environmental certification among the countries, and removing the technology and trade barriers.
Noise |
noise at boundary of plant, area noise |
Domestic wastewater |
PH, COD, SS, BOD5, oils and fats |
Industrial wastewater |
PH, color, COD, SS, NH3-N, fluoride, TOC, total phosphorus, total nitrogen, sulfate, fluoride, heavy metals |
Industrial exhaust gas |
HF, HCl, sulfuric acid mist, SO2, NO2, H2S, formaldehyde, benzene toluene, xylene, acetophenone, styrene, isopropyl, the total non-methane hydrocarbons, tin, lead, niff, particulate, PM10 |
Waste |
extraction toxicity, corrosivity, Acute toxicity, etc. |
Boiler air pollution |
SO2, Nitrogen oxides, Black degrees, Dust, Smoke opacity |
Eatery air pollution |
Cooking fume |
The testing for the occupational health and safety in workplace
China attach great importance to occupational health work. Not only promulgated " Code of Occupational Disease Prevention of PRC ", and also adopted a series of effective measures to ensure "the sampling criterion for monitoring toxic substances in the air of workplace " issued by the Ministry of Health of PRC, and other 86 Chinese occupational health standards put into practice. In order to protect the health of workers.
| Chemical factors |
Organic |
Isocyanate ester compounds, Aliphatic amines, Aromatic compounds, Organic phosphorus, Organochlorine compounds, Aromatic hydrocarbon compounds, Paraffin, Anhydride compounds, Phenolic compounds Dichloroethylene, Trichloroethylene, Tetrachloroethylene |
| Heavy Metal |
Cd, Pb, Cr, Sn, Na, Hg, Ni, Sb, Ba, Be, Bi, Co, Mg, Cu, Li, Mo, Zn, As, Se, Inorganic carbon-containing compounds, Inorganic phosphorus-containing compounds |
| Particles |
Plant lustration, suspended particulates, inhaleble particulate, Dust |
| Physical factors |
pharosage, fresh air , Temperature, Humidity, static pressure difference, Air pressure |
Environmental testing and evaluation
PONY TEST provides environmental impact evaluation, and the correlative testing including water, soil, air, rejectamenta, noise, etc. Environmental impact evaluation for the project in field of light industry, weave, chemical fibers, chemical engineering, petrochemical and pharmaceutical, machinery, electronics, thermal power, construction, municipal public works, building materials, water conservancy , hydropower, regional development, the airport and related projects, the transport。
| Noise |
noise at boundary of plant, area noise, Traffic noise |
| Ground water |
quality standard for ground water (GB/T 14848-93) |
| Surface water |
Environmental quality standards for surface water (GB 3838-2002) |
| Industrial circulating water /cooling water |
The design specifications of industrial circulating water /cooling water |
| Soil/plant |
Heavy metals, BHC, DDT, ph, pesticide residues, available phosphorus, organic mercury, organic matter |
| Flue gas monitoring |
Dust, SO2, Nitrogen oxides,NO,HCl,Pb,Cd,Hg,black degree |
| pollutants Monitoring |
HF,HCl,SO2,NO2,H2S,formaldehyde,benzene,toluene,xylene,acetophenone,Nitrogen oxides,TVOC,styrene,isopropyl alcohol,the total non-methane hydrocarbons,tin,lead,niff,particulate,PM10,methyl mercaptan |
Reference ambient air quality standard |
gas station and depot testing
In accordance with state regulations for oil and gas emission limits, technology requirements and testing methods of gas stations and oil depots.
| oil and gas emission of gas station |
Gas-liquid ratio, the obturation of system, Liquid resistance, Concentration of oil and gas |
Testing for oil depot |
Concentration of oil and gas |
Testing for architecture project and fitment acceptance
After fitment, the pollutants volatilizing from all kinds of decorative materials and furniture in house are harmful to human health. According to the research by U.S. environmental protection agency, the concentration of indoor carcinogen is 5-70 times higher than outdoors, the main pollutants are formaldehyde, benzene, toluene, ammonia, xylene, ethyl benzene, TVOC and radon from fitment.
PONY TEST can provide you professional air testing for your new house, assuring you live in a safe and healthy environment.
| Air quality testing for engineering and fitment acceptance |
Benzene, toluene, formaldehyde, ammonia, ethyl benzene, xylene,TVOC,radon |
| Testing for interior decoration materials |
Soluble heavy metals(Pb,Cd,Cr,Hg),free formaldehyde, formaldehyde, volatile organic compounds, total volatile organic compounds,benzene,xylene,toluene,heavy metals,vinyl chloride monomer,styrene |
NOTES:
Must close the doors and windows for 12 hours before testing;
Avoid opening air-conditioning or ventilation fans before and during testing;
Do not leave any decoration at the site, such as: board, paint, dope, etc.;
The owners’ should be cooperative in determining test points.
Vehicle internal air quality testing
With more and more people have their private car, the impact to the health of vehicle internal air quality is concerned by more and more people.
Due to the space in car is small and with high obturation, the pollutants are difficult to be volatilized. It is easily to be harmful to health. From the 1980’s and 1990’s, many EU countries began to pay attention to the problem of air pollution in cars. Japanese, U.S.A. and Korea follow up to research it.
PONY TEST provides professional testing service to let you know the air quality of your car.
Air quality test for various sites
The pollutant from the new decorated office, modern office facilities and the confined space of commercial buildings harm people’s health.
According to the Statistic of Hong Kong environmental protection Department, the air quality in 37.5% buildings exceeded the standard. Via researching by Canada Joint Trade Unions, there are 40,000 employees reduce at least 100,000 working days per year due to the air pollution of office.
PONY TEST provides professional air quality test for office, hospital, entertainment and shopping place.
Environmental test for office and workshop
Nowadays, most enterprises passed the ISO14000 system and OHSAS18000 system, for pushing these two systems, the test for environment and healthy factors should be done.
Such as: the testing item of ISO 14000: waste water, exhaust gas, noise of factory boundary, etc;
The testing item of OHSAS18000: drinking water, pharosage, air quality of workshop, occupational noise, etc.
|